1055_b_w.jpg (15916 bytes)

pH/ORP/ISE Sensors WITHOUT preamplifier Hook-Up Schematic

pH/ORP/ISE Sensors WITH preamplifier Hook-Up Schematic

pH/ORP/ISE Sensors with Mini External Preamplifier Hook-Up Schematic

Guide to quick disconnect Q7M/Q7F snap cable system for Rosemount transmitters

Contacting Conductivity Sensor Hook-Up Schematic

Toroidal Conductivity Sensor Hook-Up Schematic

Model 1066 Single Channel pH, ORP, Contacting and Toroidal Conductivity 2-Wire Transmitter & Analyzer

  • Chemically & Mechanically Resilient Polycarbonate NEMA 4X / CSA 4 IP66 Enclosure - Standard 1/2 DIN Cutout
  • 2-Wire Loop-Powered 24VDC Power Operation with scalable 4-20mA analog current loop output standard
    • Second 4-20mA loop-powered output available to send process temperature reading in addition to measured analytical liquid parameter
  • Automatic Temperature Compensation via 100 or 1000 Ohm Platinum Temperature Compensation Element (Available in Standard and ACCU-TEMP fast response configurations)
  • HART 7 is Standard and Foundation FieldBus available as an optional digital output
  • Large LCD Display with touch membrane keypad - Menu Driven Interface and Programming
  • Automatic Temperature Compensation from 0 to 150 °C (32 to 302 °F) for pH/ORP and 0 to 200 °C (32 to 392 °F) for Conductivity
  • Area Classifications:
    • Intrinsically Safe (with appropriate safety barrier) for:
      • CSA/UL Class I, II, III, Div. 1 Groups A-G T4 Tamb = -20°C to 65°C
      • ALTEX Baseefa04ATEX0195X EEx ia IIC T4 Tamb = -20°C to 65°C
      • IECEx BAS 11.90098X EEx ia IIC T4 Tamb = -20°C to 65°C
    • Non-Incendive:
      • CSA/UL Class I, Div. 2, Groups A-D Dust Ignition Proof Class II & III, Div. 1, Groups E-G NEMA 4X Enclosure T4 Tamb = -20°C to 65°

1066 Product Specifications

1066 Operation Manual

Measurement

Input

Measurement Range

Outputs

Calibration Points

Compatible Sensor(s)

Special Features

pH/ORP Single or Dual Channel
- pH/ORP
- 0 to 14 pH  (standard)
- Fully Scalable from 1 to 13 pH units
- Analog  0-20 mA or 4-20 mA output for pH/ORP/ISE or temperature for each input channel
- Optional HART or ProfiBUS Digital Outputs
- 2 point auto buffer recognition for pH for slope determination
- 1 point user defined pH standardize calibration to correct for offset (drift)
- Any Suitable ASTI pH/ORP  Sensor with 100 or 1000 Ohm Platinum TC
- Any Suitable ASTI pH/ORP  Sensor with 100 or 1000 Ohm Platinum TC & 1056 compatible preamplifier
- Excellent option for severe service pH & ORP measurement in areas with flammable gas and corrosive environments.
Contacting Conductivity Single or Dual Channel
- Conductivity Cell
- Cell from 0.01 to 10.0, user selectable
- Ranges from 0-200 microSiemens (0.01/cm) to 0-200 milliSiemens (10.0/cm) as mates with cell
- Analog  0-20 mA or 4-20 mA output for Conductivity or temperature for each input channel
- Optional HART or ProfiBUS Digital Outputs

- Zero Calibration (Capitance)
- Cell Constant calibration tofFind exact effective (apparent) cell constant in standard solution or process media

- Any Suitable Contacting Conductivity  Sensor with 1000 Ohm Platinum TC

- Support for displaying in concentration units of acids, bases and electrolytes as well as salinity
- Special ultrapure water temperature compensation and support for display in resistivity units

Toroidal Conductivity (Contactless Inductive) Single or Dual Channel
- Toroidal Conductivity Sensor
- Range from 0.050 to 2,000 milliSiemens (2 Siemens) - Analog  0-20 mA or 4-20 mA output for Conductivity or temperature for each input channel
- Optional HART or ProfiBUS Digital Outputs
- Zero Calibration (Capitance)
- Cell Constant calibration tofFind exact effective (apparent) cell constant in standard solution or process media
- Any Suitable Toroidal Conductivity  Sensor with 20/20 Windings and 1000 Ohm Platinum TC

- Support for displaying in concentration units of acids, bases and electrolytes as well as salinity
- Excellent choice for strong acid, strong base and strong electrolyte solutions at elevated temperatures